North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Frequency:
50Hz, 60Hz for Option
Rated Voltage:
400/230V, Various Voltage Available
Controller:
Smartgen 6110 (Deepsea for Option)
Function Option:
ATS, AMS, Synchronization, High Voltage, etc
Generator Type:
Open Type/Silent Type /Container Type/Trailer Type
Quality Standard:
ISO9001
Alternator:
Kaijie (Leroy Somer, Stamford for Option)
Export Market:
Globally
Cooling Method:
Water Cooling
Stroke:
Four Stroke
Installation Method:
Fixed
Type:
Basic Diesel Generator
Output Type:
AC Three Phase
Product Description
Product Description-250KVA Silent Diesel Generator Set With Cummins Engine
1. Powered by Cummins Engine 2. With Stamford / Leroy Somer / Marathon Alternator 3. With CHINT / ABB MCCB & Electronic Components 4. Electric Start with Battery 5. Base Integrated Fuel Tank 6. ATS, Deepsea / ComAp / Smartgen Controller 7. Comply with ISO9001/CE 8. After-sale Services
Cummins Diesel Generators Power From 20kVA up to 1500kVA, with compacted structure and best configuration.
OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 company owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards.
Control Systems
Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears.
LED Automatic Control Panelis a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory.
AMF Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator set.
ATS(Fully Automatic) is the standard configure of emergent power system. It detects the voltage and frequency of main power timely. While there is something wrong, such as high voltage, low voltage, phase missing, electricity cutting off, etc., it will signal to start the generator set automatically; While main power resumes balanced, it controls the generator set to shut down after cooled.
Engine *Heavy duty diesel engine *Four stroke, water cooled *12V and 24V stater and charge alternator *Cooling radiator and fan *Maintenance free battery including ract and cable *Flexible fuel connection hoses and manual oil sump drain valve *Exhaust silencer Alternator *Brushless, single bearing, flexible disc *Insulation class: H *Protection class: IP23 *Self-exciting and Self-regulation Canopy *All canopy designed with modular principles *All metal canopy parts painted by electrostatic polyester power paint *Soundproof design ensure that the noise level be controlled in small scope *Convenient to lift and move *Easy to maintenance and operate
Base Frame *Base frame including position for forklift and crane *Integral fuel tank *Daily fuel tank continuously supply for 8-24 hours *Fuel tank easy to maintain and clean *Anti-vibration pads are flexed between engine and alternator.
Control System *Control, monitor and protect the Generator Set including: *High water temperature *Low oil pressure *Over and under speed *Over current *Under/Over generator voltage *Start and stop failure *Low and high battery voltage *Charge fail *Emergency stop
Genset
Model
Prime Power
Standby Power
Engine Model
Cylinder
Bore×Stroke
Aspiration
Disp.
Alternator
Dimension
Weight
KVA/KW
KVA/KW
mm
L
KaiJie
Stamford
L×W×H(mm)
kg
KJC300
275 / 220
300 / 240
NT855-GA
6L
140×152
Turbo.&Intercooled
14
KTFW220
HCI444D
2750×1100×1650
2400
KJ-C330
300 / 240
330 / 264
NTA855-G1A
6L
140×152
Turbo.&Intercooled
14
KTFW240
HCI444D
2750×1100×1650
2500
KJ-C360
313 / 250
350 / 280
NTA855-G1B
6L
140×152
Turbo.&Intercooled
14
K-TFW250
HCI444ES
2750×1100×1650
2600
KJ-C390
350 / 280
387.5 / 310
NTA855-G2A
6L
140×152
Turbo.&Intercooled
14
K-TFW280
HCI444E
2800×1100×1700
2900
KJ-C400
375 / 300
412.5 / 330
NTA855-G4
6L
140×152
Turbo.&Intercooled
14
K-TFW300
HCI444FS
2800×1100×1700
3000
KJ-C420
400 / 320
450 / 360
NTAA855G7A
6L
140×152
Turbo.&air to air cooled
14
K-TFW320
HCI444F
2900×1100×1700
3350
KJ-C500
450 / 360
500 / 400
KTA19-G3
6L
159×159
Turbo.&Intercooled
19
K-TFW360
HCI544C
3000×1200×1750
3500
KJ-C550
500 / 400
550 / 440
KTA19-G4
6L
159×159
Turbo.&Intercooled
19
K-TFW400
HCI544C
3200×1200×1750
3600
KJ-C600
563 / 450
625 / 500
KTAA19-G5
6L
159×159
Turbo.&air to air cooled
19
K-TFW450
HCI544D
3200×1200×1800
3800
KJ-C680
600 / 480
660 / 528
KTA19-G8
6L
159×159
Turbo.&Intercooled
19
K-TFW480
HCI544E
3500×1500×2000
4000
KJ-C688
625 / 500
688 / 550
KTAA19-G6A
6L
159×159
Turbo.&air to air cooled
19
K-TFW500
HCI544FS
3500×1500×2000
4550
KJ-C825
750 / 600
825 / 660
KTA38-G2
12V
159×159
Turbo.&Intercooled
38
K-TFW600
LVI634B
4200×2100×2400
6000
KJ-C880
825 / 660
900 / 720
KTA38-G2B
12V
159×159
Turbo.&Intercooled
38
K-TFW660
LVI634C
4500×2200×2500
6500
KJ-C1000
900 / 720
1000 / 800
KTA38-G2A
12V
159×159
Turbo.&Intercooled
38
K-TFW720
LVI634D
4500×2200×2500
7000
KJ-C1100
1000 / 800
1100 / 880
KTA38-G5
12V
159×159
Turbo.&Intercooled
38
K-TFW800
LVI634E
4800×2300×2500
7500
KJ-C1238
1125 / 900
1237.5 / 990
KTA38-G9
12V
159×159
Turbo.&Intercooled
38
K-TFW900
LVI634F
4850×2300×2500
8000
KJ-C1400
1250 / 1000
1375 / 1100
KTA50-G3
16V
159×159
Turbo.&Intercooled
50
KTFW1000
LVI634G
5000×2300×2500
12000
KJ-C1650
1400 / 1120
1500 / 1200
KTA50-G8
16V
159×159
Turbo.&Intercooled
50
K-TFW1200
PI734B
5000×2300×2500
12500
Anhui Kaijie PowerTechnology Co., Ltd. is a professional manufacturer, specializing in production, design, sales, installation, maintenance and service of generator sets with CUMMINS, PERKINS, DEUTZ, Volvo, MTU, DOOSAN, Quanchai, Shangcai, Weichai, Yuchai, etc. Series world famous diesel engine and STAMFORD, LEROY SOMER, MARATHON, KAIJIE series AC alternators. Kaijie series generator set power range is from 10kVA-2500kVA. We believe that it is our assurance of quality and exceptional communication skills in generation set field as well as our competitive prices and professional service that will always mean your best choice. Comply strictly with ISO9001: 2008 Quality System, We always maintain the high quality of transmission and the standard of reliability, safety, durability as well as economy and environment-friendliness. And has formed a completed pre-sale, sale and after-sale service system. Win customers with quality; Stand in the market with credit; Redound upon society with value; Call on innovation and humanism, try our best to serve customers base on novel design and integrated service! Customers' satisfication, our traget!